Skip to content
CHINZYSUPER INTELLIGENCE INFRASTRUCTURE
Console ↗

CHINZY / FDE and robotics acceptance fieldbook / 09

Handling success and part damage

After transfer inspect the part and contact surfaces against agreed appearance criteria. Delivery with a new scratch can pass the motion step but fail part acceptance.

Test setup

Freeze the workcell, fixture and capture settings using samples or replay logs. Judge motion completion, correct labels and reusable data packages separately. Retain exceptions by batch.

Contrasting examples

Figures and IDs are illustrative fixtures, not product results or contract terms. Save inputs, versions and conditions before repeating an unexpected result.

Example inputExpected observation
moved=yes; before=intact; after=scratched; agreement=no_new_scratchesmotion=complete; part=fail
moved=yes; before=intact; after=intact; agreement=no_new_scratchesmotion=complete; part=pass

Recording the result

Keep a separate row for each example; one pass cannot stand in for the other. Enter the actual output, evidence location, environment version and review decision. Leave unresolved results open.

Download test worksheet (CSV) ↓

Related project guide ↗

Download an RFQ template →